Features
- Compatibility
- All Underfloor Heating
- Flooring Edges
- V Groove
- Flooring Finish
-
- Lacquer specification - UV Lacquer, Permadur high finish (3 coats)
- Coating (lacquer) thickness: 40-50μm, Gloss level: 15% +/- 3%
- Surface: rustic
- Dark Brown Synthetic Resin used to fill knots
- Flooring Fitting Type
- Fast Fit
- Flooring Format
- Single Plank
- Flooring Surface
- Smooth
- Grain
- Open Grain
- Restoration
- Fully restorable
Specifications
- Backing Material
- Spruce - Grade 2/3 (Softwood) (1.2mm)
- Colour Description
- Light Grey Oak
- Construction
- 3 Layered Board - Click System
- Finish
- Matt
- Glue/Resin
-
- Urea - Resin
- Lacquered
- Matt Lacquered
- Material
- Real Wood
- Moisture Content
-
- 5% - 9%
- Moisture Resistant
- Moisture Resistant
- Pack Size
- 6
- Product Type
- Engineered
- Resistance to Staining
-
- Resistant DIN 68861, Group A
- Room Suitability
- Bedroom, Conservatory, Dining Room, Hallway, Kitchen
- Supplied With
- 6 Full planks or 5 full and 2 halves
- Thermal Conductivity
- 0.14 W/mK
- Thermal Resistance
- 0.076(m²K)/W
- Timber Species
- European Oak veneer
- Underlay
- No Integrated Underlay
- Veneer Timber Species
- Oak veneer
Product Measurements
- Length
- 2200mm
- Maximum Length of Timber Shake
- 200mm
- Maximum Room Dimensions - Length
- 10m
- Maximum Room Dimensions - Width
- 10m
- Maximum Width of Timber Shake
- 5mm
- Pack Size Volume
- 2.77m²
- Thickness
- 14mm
- Weight (Without Packaging)
- 23.219kg
- Width
- 180mm
Guarantees & Accreditations
- Abrasion Class
-
- IP 500 revf. falling sand method
- Guarantee
- 15 Year Manufacturer's Guarantee
- Impact Resistance
-
- >1200mm EN 438-2, 12
- Reaction to Fire
-
- Cfl - S1 En ISo 11925-2
- Slip Resistance
-
- 0,5 - 0,7 u
- Guarantees and accreditations
Installation
- Care and Maintenance
-
- Move furniture carefully to avoid damaging the top layer surface
- Do not use steam mops or cleaners
- Direct sunlight may have an effect on the colour of the floor over a period of time
- Self-adhesive pads and castor cups should be fitted to furniture to avoid scratching where applicable. Note: Heavy scratching could break the seal on the flooring causing damage
- Do not use cleaning agents containing wax, polish or oil
- Use the floor exclusively under the recommended conditions outlined in the instructions
- Do not leave standing water on the floor, wipe up any spills immediately
- General cleaning of the floor should be done using a soft broom or vacuum cleaner
- A well rung out mop can also be used periodically, however avoid the use of excess water
- We recommend that floor mats are used at entrances to the property - this will help avoid abrasive particles damaging the surface
- Fitting Instructions
-
- For full details please see the fitting instructions supplied with the flooring.
- Important Notes
-
- Remove all previous floor coverings
- For timber based sub-floor, lay Bitumen Moisture Barrier Paper
- Use SDH0900 - Howdens 2mm Foam underlay & SDH0909 High Performance Underlay (XPS)*
- Flooring should be kept in the room where they are to be laid for 48 hours or more to allow them to acclimatise to the ambient temperature and humidity
- If laying over a stone/mineral sub-floor, lay SDH0910 - Howdens Damp Proof Membrane (at least 0.2mm thick PE foil) first as a "trough" (i.e. lay over the floor and extend ends and sides up the walls for a few centimetres) or SDH0931 Paintable Damp Proof Membrane
- The maximum area without additional expansion joints is 10m width x 10m length
- Sealed packs must be stored for at least 48 hours where they are to be laid. Do not open packs until you are ready to install the flooring. Packs are to be laid flat on the floor with at least 50cm between packs and walls. Packs should be stored in a room with a minimum temperature of 18°C
- Do not install cabinets over the floor
- As a natural oak product, the knots that appear are a characteristic of natural timber. To keep these knots in place and prevent splitting they are sealed with dark brown filler
- We recommend that heating should have been operating in the room for at least two weeks to ensure a stable temperature level
- Must leave 15mm expansion gap around the entire floor including cabinet legs, radiator pipes and door frames
- Not suitable for use in unheated rooms, damp rooms or bathrooms
- Moisture test must be carried out for all mineral based substrates (2.0 CM % for cement screed and 0.5 CM % for sulphate screed), a room temperature of 20°C(68°F), a relative humidity of about 50-60% should be maintained
- High performance Underlay (XPS) is not suitable when using underfloor heating
- Laying Detail
- Must be laid as a floating floor (see instructions)
- Suitable for Underfloor Heating
- Yes - Electric and radiant if installed as per the instructions (note must not exceed 27 degrees)